Complete 20x20cm system with GRM CAPGRM and EBGRM

The vertical complete modular systems provide a fully intergrated solution within one gel tank for both two-dimensional electrophoresis and electroblotting. These systems are available in a range of sizes and comprise gel-running modules designed specifically for denaturing or native page, capillary gel isoelectric focusing and electroblotting. Following 2-D electrophoresis, the electroblotting module can be used to transfer second dimension SDS-PAGE gels for further analysis by western blotting, providing enhanced sensitivity.

Benefits Include:
CAPGRM – for first dimension electrophoresis of up to 10 ampholyte capillary gels, a maximum 8 or 17cm in length and 1 or 4mm in internal diameter.
Twin-plate standard GRM – designed specifically for SDS-PAGE techniques requiring self-cast gels, although commercially available 10 x 10cm precast gels may be used in the TV100-GRM
Twin-cassette EBGRM – allows simultaneous transfer of 2 polyacrylamide gels in colour-coded electroblotting cassettes, while plate-electrodes only 6cm apart maximise the intensity of the electric field.
Casting base and cooling – included as standard – act in tandem with glass plate stops within the GRM to lock the plates firmly in position on the casting base. Whereas snap-lock connectors allow the cooling unit to be connected to a chiller unit for high voltage/current separations.
Colour-coded combs and spacers – available in 1 and 1.5mm thickness

Technical Specification

Unit Dimensions38 x 15 x 27.5cm
Inner Tank Dimensions27 x 12.5 x 25cm
Plate Dimensions 20.5 x 20 x 0.4cm
Standard Spacer Dimensions 2 x 20 x 0.1cm
Active Gel Dimensions 16.5 x 17.5cm
Maximum Sample Capacity 2 x 1/2 x 24
Recommended Buffer Volume Inner Buffer Chamber 700ml
Gel Tank 4200ml
Recommended Running Conditions Voltage200-300V
for Denaturing/Native PAGE gelCurrent 30-40mA
Time 2-2.5h
Capillary DimensionsInner Diameter 1mm
Outer Diameter 5mm
Length 170mm
Recommended Buffer Volume Upper Buffer Chamber 300ml
(capillary) Gel Tank 4200ml
Distance Between Plate Electrodes 6cm
In EBGRM
Electroblotting Cassette Dimensions 20.5 x 20cm
Active Transfer Area 289cm
Recommended Running Conditions Voltage200V
For ElectroblottingCurrent150mA
Time 6h to overnight
Casting Base Silicone Seal Dims 1.7 x 22.5 x 0.8cm
Power Output Shrouded, 4mm
Connectors (diameter)
Recommended Running Conditions Pre-Run SeparationEnd of Run
for IEF of Capillary Gels
Voltage 200V400V 500V
Time 0.5h 6-18h0.5h
Volt-Hours 100Vh 2400-7200Vh 250Vh