Complete 10x10cm system with GRM CAPGRM and EBGRM
TV100YK-MODSYS
Complete 10x10cm system with GRM CAPGRM and EBGRM
List Price
£ 1,254.00
Please Call +44 (0)1582 455135 for stock availability
Quantity  
Buy

There are currently no product reviews for this item.

Complete 10x10cm system with GRM CAPGRM and EBGRM

The vertical complete modular systems provide a fully intergrated solution within one gel tank for both two-dimensional electrophoresis and electroblotting. These systems are available in a range of sizes and comprise gel-running modules designed specifically for denaturing or native page, capillary gel isoelectric focusing and electroblotting. Following 2-D electrophoresis, the electroblotting module can be used to transfer second dimension SDS-PAGE gels for further analysis by western blotting, providing enhanced sensitivity.

Benefits Include:
CAPGRM – for first dimension electrophoresis of up to 10 ampholyte capillary gels, a maximum 8 or 17cm in length and 1 or 4mm in internal diameter.
Twin-plate standard GRM – designed specifically for SDS-PAGE techniques requiring self-cast gels, although commercially available 10 x 10cm precast gels may be used in the TV100-GRM
Twin-cassette EBGRM – allows simultaneous transfer of 2 polyacrylamide gels in colour-coded electroblotting cassettes, while plate-electrodes only 6cm apart maximise the intensity of the electric field.
Casting base and cooling – included as standard – act in tandem with glass plate stops within the GRM to lock the plates firmly in position on the casting base. Whereas snap-lock connectors allow the cooling unit to be connected to a chiller unit for high voltage/current separations.
Colour-coded combs and spacers – available in 1 and 1.5mm thickness
Technical Specification
Unit Dimensions28 x 15 x 18cm
Inner Tank Dimensions16.5 x 11 x 15cm
Plate Dimensions 10 x 10 x 0.2cm
Standard Spacer Dimensions 1 x 10 x 0.1cm
Active Gel Dimensions 8 x 8.5cm
Maximum Sample Capacity 2 x 1/2 x 12
Recommended Buffer VolumeInner Buffer Chamber 90ml
Gel Tank 1600ml
Recommended Running Conditions Voltage100-150V
for Denaturing/Native PAGE gelCurrent 10-15mA
Time 1-1.75h
Capillary Dimensions Inner Diameter 1mm
Outer Diameter 5mm
Length 80mm
Recommended Buffer Volume Upper Buffer Chamber 200ml
(capillary) Gel Tank 1600ml
Distance Between Plate Electrodes6cm
In EBGRM
Electroblotting Cassette Dimensions 11.5 x 10.5cm
Active Transfer Area 71cm
Recommended Running Conditions Voltage100V
For ElectroblottingCurrent 75mA
Time 4-6h
Casting Base Silicone Seal Dims1.5 x 11 x 0.8cm
Power Output Shrouded, 4mm
Connectors (diameter)
Recommended Running ConditionsPre-Run SeparationEnd of Run
for IEF of Capillary Gels
Voltage200V400V 500V
Time 0.5h 3h0.5h
Volt-Hours 100Vh 1200Vh 250Vh
Email to a colleague