ABEZ-1000R
Tips EZject Reload 100-1000ul Pk1000
> Stock up today - Buy any 20 or more packs of the same type and SAVE 20%
> Stock up today - Buy any 10 or more packs of the same type and SAVE 15%
List Price
£24.00
In Stock
Quantity  

Tips EZject Reload 100-1000ul Pk1000

EZject Pipette Tips
A revolutionary new tip design reduces ejection forces bringing you greater pipetting comfort.
Studies carried out on a wide range of standard manual pipettes have shown that ejection forces can typically be in the region of 4kg. Ejection forces are seriously affected by the amount of force used to mount the tip onto the pipette. When using traditional tips many scientists will employ a ‘pounding’ or ‘slamming’ motion to ensure the tip is fitted secure to the pipette shaft. This need is compounded when using a lower quality ‘universal fit’ tip that is poorly designed and manufactured and does not fit pipette shaft correctly.
Consequently, due to high forces used to mount the tip, the ejection force then required to remove it is also significantly increased, resulting in high forces exerted on the user every time a tip needs changing.
However, avoiding this can be inexpensive and straightforward. Combining good laboratory practices with quality pipettes and tips, that are well maintained, can substantially reduce the strain involved in pipetting and will improve your accuracy and precision.
At Anachem we strive to provide our customers with the most innovative and effective solutions to everyday laboratory issues. As Repetitive Strain Injuries (RSI) and high pipetting forces are of paramount concern to scientists everywhere, we are introducing a new pipette tip option that offers you reduced ejection forces without compromising on your accuracy and precision. And, the great news is these tips will fit most of the pipettes you already have in the laboratory.
Anachem’s New EZject Pipette Tips utilise a unique bi-fabricated wall creating a soft, flexible seal. This design ensures a secure seal is formed when applying a fraction of the force normally required to mount standard tips.
Pipetman and Anachem’s EZject Tips have been evaluated in Anachem’s Pipette Service Centre to ensure that the system provides the accuracy and precision you rely on from your Pipetman.
These results show that both sizes of tips when used with Pipetman perform well within Gilson specifications. So you will not have to compromise on accuracy and precision when using EZject tips and will benefit from improved comfort.

Systematic Error (µL)
Random Error (µL)
Model of Pipette
Volume (µL)
Gilson Max
Permissible Errors
EZject Results
Gilson Max
Permissible Errors
EZject Results
P1000
200µL
+/- 3.0
0.547
≤0.60
0.221
1000µL
+/- 8.0
0.366
≤ 1.50
0.119